Industrial Water-Cooled MIG/MAG Welder System
- Features
■ Adopt the soft switch technology, high efficiency, low power consumption
■ Automatic protection from overcurrent, overheat, over/under voltage
■ Support digital display and presetting of current and voltage, wide adjustment range of voltage
■ Particular function of automatically removing melting-ball from the end of the welding wire
■ Adopt the closed-loop system to control arc and waveform control system to adjust the arc force
■ Suitable for low carbon steel and low alloy carbon with solid/flux-cored welding wires of different
specifications
■ Widely used in such areas as automobile, shipbuilding, bridge, petrol chemistry and construction,
and so on
■ A voltage fluctuation of ±20% is allowable
■ Small size, light weight
■ Support frequent welding, little spatter, high efficiency in melting metals
■ Support MIG welding, MMA welding
2.Main Parameters
|
Type Contents |
NBC-350 |
NBC-500 |
NBC-630 |
NBC-800 |
|
Power source |
3-phase 380V /415V 50/60Hz |
|||
|
Rated input current |
22A |
36A |
52A |
68.5A |
|
Rated input capacity |
14.5KVA |
24KVA |
34KVA |
45KVA |
|
Rated welding current/voltage |
350A/31.5V |
500A/40V |
630A/44V |
800A/44V |
|
Welding current |
60% |
60% |
60% |
60% |
|
65V |
65V |
80V |
80V |
|
|
No-load voltage (MAX) |
40-350A |
20-500A |
40-630A |
40~800A |
|
Adjust. range of welding curr. |
83% |
83% |
83% |
83% |
|
Efficiency |
83% |
|||
|
Power factor |
>0.95 |
|||
|
Time for pre-gas sending |
0~1S |
|||
|
Time for delay gas sending |
0~4S |
|||
|
Diameter of wire |
Ф0.8~Ф1.6mm solid/flux-cored wire |
Ф1~Ф1.6mm solid/flux-cored wire |
||
|
Air switch |
32A |
40A |
63A |
100A |
|
Dimensions (mm) |
590×306×500 |
640×326×560 |
651×356×665 |
680×386×730 |
|
Input cable (mm2) |
3×4+1×2.5 |
3×6+1×4 |
3×10+1×6 |
3×10+1×6 |
|
Insulation class |
F |
|||
|
Protection class |
IP21 |
|||